簡單介紹 * Includes non-linearity hysteresis and non-repeatability at a fixed temperature,美國controller 855系列板貼裝壓力傳感器*18-24VDC input required for 1-10VDC output*
0/0.25"WC up to 0/15PSI (bi-directional ranges available)
Compensated Range:
10° to 50°C
Adjustments:
Offset, 60% of FSO minimum
Media:
Non-corrosive, non-ionic gases
Operating Humidity:
90% RH non-condensing
Operating Temp:
-25° to 70°C
Input Supply:
12-24 VDC
Supply Current:
<10ma<>
Load Resistance:
2KΩ minimum
Output Signal:
1-5VDC, 1-6VDC, 1-10VDC** (call for custom outputs)
Electrical Connections:
0.025" square pins on 0.1" centers (5) – Board-Mountable***
Pressure Connections:
Barbed fitting for 1/8" ID tubing
Dimensions:
Approx. 1.50" x 1.35" x 0.9" (3.81cm x 3.43cm x 2.29cm)
* Includes non-linearity hysteresis and non-repeatability at a fixed temperature ** 18-24VDC input required for 1-10VDC output *** Direct-to-board solder connection and optional cable available upon request
Package Drawing
CLICK TO ENLARGE
How to Order
A typical order number consists of the model number, pressure range, pressure unit, output and mounting connection.
Model
Type
Output Signal
FSO Pressure Range
Calibration Pressure
855
D = Differential or Gage*
0…..1 to 5 volts
0…..0.25"WC to 5"WC
Customer designated exact FSO
1…..1 to 6 volts
1…..>5"WC to 13" WC
2…..1 to 10 volts**
2…..>0.5PSI to 1PSI
5…..Custom Output
3…..>1PSI to 5PSI
4…..>5PSI to 15PSI
Example: 855D 5" 12D 0 (Model number 855, differential or gage type unit, pressure range of 0-5" WC, output signal of 1-5 VDC)
* With a gage application, one of the two ports is vented to atmosphere ** Requires 18-24 VDC input
Note: This unit is not designed to support any capacitive load on the output. Please contact Controller Sensors LLC for additional installation guidance