MFM 6100
Two-Phase Mass Flow Meter
The Correflow MFM combines the technology of two patented measurement techniques (velocity and concentration) in a single sensor to achieve a measurement of mass flow. The first measurement determines the two phase slurry velocity and the second measurement determines the fraction of one of the phases of the mixture in relation to the other. Combining these two parameters yields mass per unit time (ie. mass flow).
Two Component Concentrations: 1% to 99%
Materials: Insulating liquids, solids (particulate), gas (bubbles or as carrier)
Typical Response Time: Concentration–updated at 2.5 millisecond intervals using last measured velocity; Velocity–typically updated once per second
Purge Option: Type Z purged (NEMA 4X): Cl1, Div 2, GR C&D
European (Eex approved) housing also available
Sensor: Typical Sensor Pipe sizes: 1/8” (.32 cm) ID or greater
Pressure limits: 1000 psi (69 bar) typical for small sensors, Higher pressure designs available. No moving parts, no flow restrictions or additional pressure drop
Power Requirements: 115 to 240 VAC, 50 to 60 Hz (100 Watts maximum)
Instrument air for optional pressurization(intermittently 4 scfm @ 80 to 120 psi)
Data Analysis Velocity, volume fraction, mass fraction, mass flow measurements on an instantaneous basis and averaged over user programmed time intervals, Total mass for fixed time intervals, Stream temperature
Calibration Routines: Sensor self-tuning with optional dynamic auto-zeroing routines; Adjustable gain on concentration and velocity measurement circuitry; Adjustable signal filtering on concentration measurement circuitry; Adjustable sampling rate for a wide range of process conditions
Software and fully installed PC available
Sensor connections designed intrinsically safe
Each sensor has Four 4-20mA outputs which are independently
programmable to any Four of 12 available parameters
MODBUS over RS485 or Ethernet communications: communication or data read out for remote parameter adjustment, calibration and testing.
Various digital and analog inputs optionally available
Benefits
Continuous analysis with selectable time averaging
No moving parts, unaffected by vibration
No additional pressure drop
Selectable output scaling
Designed intrinsically safe
Ruggedized for the factory environment
Instantaneous and average mass flow outputs
Non-contact measurement
MFM6100




















元朗区|
二连浩特市|
富顺县|
彭州市|
合川市|
开封县|
辽阳市|
类乌齐县|
华亭县|
达日县|
北流市|
洛宁县|
同仁县|
浦江县|
屏山县|
开江县|
晋州市|
敦化市|
石柱|
阜新|
丰台区|
新闻|
松溪县|
定陶县|
墨竹工卡县|
咸宁市|
凤凰县|
巩义市|
喀喇沁旗|
广东省|
松阳县|
乌拉特后旗|
闸北区|
阿克陶县|
竹北市|
荔浦县|
阳曲县|
蒙山县|
嫩江县|
浦北县|
南皮县|